The High-Voltage Capacitor (H40-0015) is .001 micro farads.    
  H40-0015 is filled with a clear mineral oil. The 2 amp breaker located  
  within the operators console may disengage if the capacitor  
  fails. Replace H40-0015 if leaking. Additionally, replace  
  H40-0015 if there are visible signs of arcing (carbon trails).  
 
  To measure H40-0015, you must have a meter that can read capacitence.  
 
 
 
H40-0015
ELECTRICAL BOX
ELECTRICAL BOX - VIEW A'