| This is an isolated bulk head fitting. | ||||||||||||||||
| When replacing this connector ensure that the yellow wire with the black | ||||||||||||||||
| marking goes to the shield and the other wire goes to the center conductor. | ||||||||||||||||
| After installing ensure that the machine will stop when an arc occurs in the | ||||||||||||||||
| automatic mode. If it does not stop try reversing the polarity (solder the | ||||||||||||||||
| yellow wire with the black marking to the center conductor and the other | ||||||||||||||||
| wire should go to the shield). | ||||||||||||||||
| ELECTRICAL BOX - VIEW D | ||||||||||||||||
| SWING-ARM | ||||||||||||||||